Iei Keypad Wiring Diagram – 1 Functions and Programming Guide Command and Control Door Guard Series Command and Control Keypads provide a field-reliable and cost-effective solution wherever control or limited access is required. Designed to individually control up to four units, Door-Guard Command and Control Series Keypads are the perfect choice for controlling electric locks, security systems, automated workers or machines. The door guard is powered from a 12 volt or 24 volt AC/DC power source. Functions: 4 Independent Outputs 4 Independent Timer Boards 8 Type C AMP Relays 120 Remote Start Input User Programmable Keypad with Codes All outputs are code or program in memory that turns on for 5 minutes, then program turns on for 5 minutes It means the code will be removed. One Year Programming Programming is done entirely from the front of the keyboard. Programming is easy with LED or buzzer guides, and authorized users code changes in seconds. The door guard command and control keypad codes accept up to 120 valid individual user codes. Codes can be 1-6 digits long and numbers can be repeated. The master code is always assigned to user location 1. Main Relay This is an 8 amp (10 amp boost) Form-C relay that can be coded or timed from 1 to 90 seconds. Auxiliary Outputs Auxiliary outputs can be individually timed from 1 second to 90 seconds or actuated as a key switch and can be turned on individually or in combination with a code. The Ruggedized (R), Sealed Environmental (Se), Multipad and Extreme styles provide this output as a 1 amp Form-C relay, while all other styles provide a negative voltage output with a 50 mA sink. Remote Trigger Input (REX) This is by default a normally open loop that, when activated, will actuate the main relay and can be programmed to trigger any combination of outputs. Outputs selected for temporary shutdown are active for the programmed amount of time. The main relay (if selected) turns on simultaneously with the main code. This feature is especially useful when controlling electric locks. Keypress Feedback/Command Series Guard and Audio Keypress Control confirms a keypress by temporarily turning on a yellow LED as in (i) or by sounding a momentary buzzer in a closed environment (se). It can be turned off programmatically. The command series saver and active keyboard output control can be programmed to activate the voltage output whenever a key is touched. It can be used to alert auxiliary devices such as lights, CCTV or security. This output is not available when using the IEI 250 printer interface. Auto-entry This function is used when it is necessary not to follow the code with the * key. Users only need to enter a code number to activate the relay for the programmed relay time. To use this feature, your code must be the same as your original code. Audit Trail * Detailed, real-time audit trail can be provided by any Command & Control series protector with an optional Model 250 printer interface. The 250 can monitor up to 8 keyboards simultaneously. Comes with a 250V power supply and printer cable and can be easily connected to any parallel line printer (not included). * This option is not available for all keyboard styles. Contact IEI or visit our website for a list of products! Version 1.04

2 1 2 Keyboard Test 1. Connect the positive (+) lead of the power supply to the +V input of the terminal strip (TS1). 2. Connect the negative (-) wire of the power supply to the terminal strip input (TS1)-V. 3. Turn on the power supply. 4. Dial *7890#123456. When all 12 keystrokes are confirmed, the keyboard goes into self-test mode. The LED will flash or the buzzer will sound 3 times, followed by a continuous light or sound for 3 seconds (except mullions). If it does not respond, retry test mode and then contact technical support. Note: Self-test mode can be used to troubleshoot keyboard issues in the field. If there is still no light or sound, the memory is corrupt and must be reprogrammed using command 46 (see option 19). 5. Enter the original code *1234. Trigger the Gizeh relay. To program your keyboard, see the Programming section. Note: The keypad can be programmed in the store or at the installation location. The programmed information is stored in non-volatile memory so that it is not lost in the event of a power failure. Command and Control Defaults Door-Guard series command and control keypads are designed for easy installation with minimal time required. These are factory programmed defaults. Main Code (User 1) 1234 The main relay turns on as an auxiliary output for 5 seconds, activating the panic output for 5 seconds. If you need to change the defaults to red green or need additional features, please read the programming section and refer to the programming options chart. Programming 1. Enter programming mode Yellow LED 1 99 # (master code) * slowly flashing 2. To change master code 2, press 1 # (new master code). * Repeat flashing rapidly (new master code) * If the master relay flashes slowly and you need to change the timing, change option 2 in the programming options chart above. 3. Press 2 to add/change the second code (new user code). # * Fast repeat flashing (new user code) * Slow flashing. 4. Press 3 to add/change the third code (new user code). # Provided * Quickly repeat flash (new) USER CODE) USER CODE) * Flashes slowly. 5. You can add up to 120 codes in this way. User codes are stored in your location. 120 user locations are available. 1 Some door protection products have a buzzer instead of a yellow LED. In these products, blinking is replaced by a beep. 2 The master code is always at the user’s location. 1. The master code allows access to programming mode and activates the master relay. All code must be followed by the * key. Codes can be 1-6 digits long and numbers can be repeated. If you have forgotten the original code or it doesn’t seem to work, briefly press SW1 (see wiring diagram) on the circuit board to enter programming mode and program the code according to the second step above. Follow the new original. A steady yellow LED (or beep) in programming mode indicates an error. Press * to clear (yellow LED should flash or beep) and start with step 2 or 3 above.

Iei Keypad Wiring Diagram

Iei Keypad Wiring Diagram

3 3 Programming Options Diagram If you need to change the pre-programmed defaults or require additional functionality, you can program the following options. 1. Enter programming mode 99 # (master code) * 2. Change master code/set master relay time 1 (see below) Press (relay time) # 1 # (new code) * (repeat code) * Example: original code 4321 /relay time 10 seconds Press 10# 1# 4321*4321*3. Add/Change User Code (User Position) # (New Code) * (Repeat Code) * 4. Add User Code to Another /CHANGE Output Press (Relay Time) # (User Position) # (New Code) * Relay Main Time 1 (See below) (Repeat Code) * 5. Delete User Code (User Position) Press Number ** 6. Set Output 2 Time 1 (See Below) 12 # (Relay Time) # 0 # ** Press 7. Set Output 3 No. 1 (see below) 13 # (relay time) # 0 # ** 8. Set output No. 4 Press 1 (see below) 14 # (relay time) # 0 # ** 9. Set output for remote trigger input 17 # (Output: 1, 2 or 2, 3, etc.) # 0 # ** Note: 0 = No Output 10. Set Output for Panic 2 (see below) 18 # Press (Output: Example: 1, 2 or 2, 3 etc.) # 0 # ** Note 0 = No output 11. Keypress before feedback/adv enabled Disable audio keypress ss 30 # 0 # 1 # ** 12. Disable keypress feedback/audible keypress 30 # 0 # 0 # ** 13. Activate yellow LED/sound with relay 30 #1 #1 # ** 14. Yellowing. LED/Sound Off Relay 30 # 1 # 0 # ** 15. Push 30 # 2 # 1 # ** 16. Activate Auto Input on Push 30 # 2 # 0 # ** 17. 30 # 2 # 0 # * Press The * 17. Exit on keypad 3 (see below) by pressing 43 # 0 # 99 # ** 18. 43 # 0 # 00 # ** 19 to disable the keyboard.

Bticino Kits And System Solutions Product Catalogue By Sentor Electrical

Iei 212i keypad manual, iei keypad change code, iei standalone keypad, iei 212 keypad, iei outdoor keypad, iei keypad programming instructions, iei 212w keypad programming, iei keypad programming, iei keypad manual, iei keypad programming manual, how to change code on iei keypad, iei 212i keypad programming